vios
美
英 
例句
Since you can only have one IVM in the JS22, you cannot use SEA failover as you can in a traditional VIOS installation.
由于在JS22中只能有一個IVM,所以不能像傳統的VIOS安裝中那樣使用SEA故障轉移。
This took a long time, as I had several disks (100+) assigned to my VIOS, and four paths to the SAN, all of which had to be scanned.
這花費了很長時間,因為我給這個VIOS分配了許多磁盤(超過100個),而且有四條到SAN的路徑,這些都必須掃描。
The VIOS on both systems must be capable of providing virtual access to all storage resources that the mobile partition is using.
兩個系統上的VIOS必須能夠向遷移分區使用的所有存儲資源提供虛擬訪問。
All the disks that are visible on the AIX client partition have to be virtual disks (exported from VIOS using virtual SCSI).
在AIX客戶機分區上可以看到的所有磁盤必須都是虛擬磁盤(使用虛擬SCSI從VIOS導出)。
With each of the GUIs, you can query the VIOS that holds the VM library to see what ISO images are available.
在這兩個GUI中,都可以通過查詢包含VM庫的VIOS查看可以使用哪些ISO映像。
These steps were to check the general health of the VIOS.
這些步驟檢查VIOS的健康狀態。
I noticed several disks were identified as having AIX installed on them, but they did not belong to my VIOS rootvg!
我注意到,識別出了幾個安裝了AIX的磁盤,但是它們不屬于我的VIOSrootvg!
Rather than mix two vendors' MPIO code on the same VIOS, it may be simpler to manage if each storage type has its own VIOS.
與在相同的VIOS混合兩個供應商的MPIO代碼相比,如果每種存儲器具有其自己的VIOS將更容易管理。
The SAN disks that are exported to the AIX client partition must be available to both the VIOS partitions on both the CECs.
導出到AIX客戶機分區的SAN磁盤必須在兩個CEC上的兩個VIOS上都可用。
Once both my VIOS were activated and I'd verified the virtual adapter mappings and health checks, I started an AIX LPAR.
在啟動VIOS并檢查虛擬適配器映射和健康狀態之后,我啟動一個AIXLPAR。
I also captured the location codes for the VIOS rootvg disks, which proved to be an important step, as shown later.
我還捕捉了VIOSrootvg磁盤的位置碼,這是一個重要的步驟。
Therefore, logical memory has to be backed by both the physical memory in the pool and by the paging devices on the paging VIOS.
因此,邏輯內存必須由池中的物理內存和PagingVIOS上的分頁設備共同支持。
Using the topas command on the source VIOS, you may observe some network traffic on the SEA (ent6) as a result of the memory copy.
在源VIOS上使用topas命令,可以看到SEA(ent6)上有一些網絡通信流,這是內存復制產生的通信流。
However, many customers run two VIOS partitions to provide redundancy and fail-over to the AIX client partition.
但是,許多客戶運行兩個VIOS,以便為AIX客戶機分區提供冗余和故障轉移。
The VIOS partition profile is also updated to reflect the removal of these virtual devices.
VIOS分區概要文件也進行了更新以便反映這些虛擬設備的刪除。
The supported devices differ between AIX and POWERVM VIOS, as well.
受支持設備在AIX和POWERVMVIOS中有所不同。
A switch of the paging VIOS partition can be initiated through the HMC command line using the chhwres command with the -so option.
可以在HMC命令行上使用帶-so選項的chhwres命令切換分頁VIOS分區。
The data LUNs had already been assigned to the VIOS and mapped and configured on the client LPAR.
這些數據LUN早已被分配給了VIOS并已在客戶機LPAR上進行了映射和配置。
The IVM automatically created a VIOS paging device for each LPAR as part of the migration to shared memory.
在遷移到共享內存時,IVM自動地為每個LPAR創建一個VIOS分頁設備。
If possible, the paging VIOS redundancy configuration for the migrated partition will be preserved on the target system.
如果可能的話,在目標系統上保持被遷移分區的分頁VIOS冗余配置。
I also ensure that we update the VIOS and LPAR partition profile (on the HMC) with these newly created virtual adapters.
我還用這些新創建的虛擬適配器更新了VIOS和LPAR分區概要文件(在HMC上)。
AIXPCM supports all devices that the AIX operating system and VIOS POWERVM firmware support, including selected third-party devices.
AIXPCM支持AIX操作系統和VIOSPOWERVM固件支持的所有設備,包括選定的第三方設備。
NPIV with a VIOS, utilizes virtual FC devices to present disk (and tape) natively to the client LPARs.
具有VIOS的NPIV利用了虛擬的FC設備來將磁盤(和磁帶)本機地呈現給客戶機LPAR。
I activated one of the VIOS and waited while it started to boot.
我啟動一個VIOS,等待它開始引導。
The VIOS on both systems must have a shared Ethernet adapter configured to bridge to the same Ethernet network used by the mobile partition.
兩個系統上的VIOS都必須配置一個共享的Ethernet適配器,通過它橋接遷移分區使用的Ethernet網絡。
If the shared memory partition has been configured to use redundant paging VIOS partitions, a common paging space device will be assigned.
如果共享內存分區使用冗余的分頁VIOS分區,那么會分配共用的分頁空間設備。
If 'no_reserve' is not set, then VIOS on the original CEC should be shut down before the switch over is done.
如果不設置‘no_reserve’,那么在執行切換之前原CEC上的VIOS應該關閉。
However, after an initial spurt, sales of the Vios have been weak.
然而,在經歷最初的井噴之后,威馳的銷售一直較為疲軟。
You can confirm the existence of this device with the lsdev command on the VIOS.
可以在VIOS上使用lsdev命令檢查是否存在此設備。
The paging VIOS partitions that you define here will be used as defaults when you later create the shared memory partitions.
在以后創建共享內存分區時,將默認使用這里定義的分頁VIOS分區。
Two LUNs from SAN storage are mapped to the two fibre channel adapters on the VIOS partition.
SAN存儲中的兩個LUN映射到VIOS分區上的兩個光纖通道適配器。
The VIOS itself can be installed on either the internal disk or SAN disk.
VIOS本身可以安裝在內部磁盤或SAN磁盤上。
Ensure VLAN configuration is done appropriately for VIOS partitions on both the CECs.
確保對兩個CEC上的VIOS分區做了適當的VLAN配置。
No reconfiguration (apart from the boot list) was required, even for the VIOS.
不需要重新配置(引導列表除外),即使對于VIOS也是如此。
If you prefer the VIOS shell prompt, there are very few commands to learn, and they're easy to remember.
如果喜歡使用VIOSshell提示符,只需學習很少幾個命令,而且很容易記住。
We then enter the OEM VIOS environment to run the pcmpath utility and obtain the LUN ids associated with each hdisk.
然后,我們進入了OEMVIOS環境來運行pcmpath實用工具并獲得與每個hdisk相關聯的LUNid。
Figure 3 illustrates a switchover of an AIX environment using a single VIOS partition.
圖3說明使用單一VIOS切換AIX環境。
After a failover, no automatic switch back will occur when the original paging VIOS partition comes up again.
執行故障轉移之后,當原來的分頁VIOS分區重新運行時,并不會自動地切換回來。
Insufficient resources in the VIO server can bottleneck the whole system.
VIOS服務器資源不足可能會造成整個系統的瓶頸。
If you want to create a non-redundant partition, set the Secondary Paging VIOS field to none.
如果希望設置非冗余的分區,那么把SecondaryPagingVIOS字段設置為none。